clm-dafb329fca5e2f46
descriptive
Because the state only forecasts the big rivers
Permanent project revision
Revision 2026-08-22-evidence-baseline · effective 2026-08-10
Current revision. This is the snapshot used by the live entity page.
Created the first structured Evidence Passport with 13 claims and 3 source dossiers.
sha256:4f6a030c21b91b1d3b559679153d2cc8be866f2c757203e6a8f5358c01769a32
add /evidencePassport — Added claim-level evidence mapping and source dossiers.add /revisionHistory — Established a permanent, hash-addressed baseline revision.The text below is copied verbatim from the published record. Each claim names the source dossiers that carry it; caveats stay attached to the claim they qualify.
clm-dafb329fca5e2f46
descriptive
Because the state only forecasts the big rivers
clm-21193489367001b4
descriptive
Nice and later the Métropole built their own gauging network on the coastal streams that flood the city
clm-44278964bb759d70
quantitative
Instrumentation started in 1983 on the Paillons, when the Liautaud tunnel was dug into the river bed
clm-de8f2ff3e5306294
descriptive
nine rain gauges, ten water-level stations and four cameras added to support crisis management on that basin
clm-7dcd9030ce48498c
descriptive
a flood alert device whose job is to evacuate and close that tunnel before flooding reaches street level
clm-366ab26dc7e48e3e
quantitative
The Magnan, which runs through the Madeleine district, was equipped from 2013 with two rain gauges, two level stations and three cameras used for image processing
clm-9b57a4dab5bb9ccf
descriptive
with alert thresholds set inside an experimental hydrovideo forecasting project fed by radar rainfall
clm-007b5a1ca06d5cfb
quantitative
As metropolitan assets the Métropole counts 14 rain gauges, 20 limnimetric stations and 7 cameras
clm-3e11c000e71fd353
quantitative
telemetered to a flood supervision system and watched by a dedicated engineering team on a 24/7 on-call rota
clm-95fcab724cab93bf
descriptive
the Var itself stays with the state's Vigicrues service
clm-9883bc32a33af1b2
descriptive
On the Paillon a duty team at the metropolitan traffic centre watches the readings and closes a tunnel
clm-915718d5140d124a
descriptive
on the Magnan the forecasting layer is still described by its operator as experimental
clm-170349f1cae6b9b0
quantitative
on the Cagne and Malvan, whose monitoring network was completed in 2019, the local alert system is, in the Métropole's own words, still being defined
This layer records what is known about each source, what is still missing, and the exact snapshot this page is rendering. A missing date, archive or hash stays visible as missing.
Awaiting operator and domain-expert review; publication of this revision implies neither.
sha256:4f6a030c21b91b1d3b559679153d2cc8be866f2c757203e6a8f5358c01769a32
src-a47854ce8099af57Operator's own page and the source of every figure used: instrumentation of the Paillons from 1983 with the Liautaud tunnel, nine rain gauges / ten limnimetric stations / four doubt-clearing cameras there, the Magnan equipped from 2013 (two + two + three cameras, experimental hydrovideo forecasting with radar rainfall), the Cagne-Malvan network completed in 2019 with its local alert system "en cours" of definition, totals of "14 pluviomètres, 20 stations limnimétriques et 7 caméras", real-time telemetry into a flood supervisor over GPRS/RTC/ADSL/fibre, a dedicated engineer team with a 7/7 24/24 on-call rota, and the state (DREAL / Météo-France, Vigicrues) keeping the Var.
src-f11d53fa1f1d2b43City page, updated 18 June 2025. Names the operational pieces from the city's side: the TRGP tunnel alert system run by the Métropole from the Centre Multimodal des Déplacements 24/7, the RAINPOL platform whose virtual rain gauges raise an alert when a threshold is likely to be reached within the next hour, the PANORAMA water-cycle supervisor, and the use of CSU cameras plus field reconnaissance teams during events.
src-eb9e20bacbc6833aSupplier case study — treated as vendor material, used only for the technical description that the Magnan stations measure level and discharge by camera (CamLevel / CamFlow) and were operational from 2013 for the City of Nice. Its performance framing is not used.