clm-d9ff281a01c63b35
descriptive
Göteborg Energi, owned by the City of Gothenburg
Permanent project revision
Revision 2026-11-11-baseline · effective 2026-11-11
Current revision. This is the snapshot used by the live entity page.
Created the first structured Evidence Passport with 18 claims and 9 source dossiers.
sha256:c3ad7502e44ceb7bc332bcf47b740cf540da77f86d195ef8d26a16384a98d2ea
add /evidencePassport — Added claim-level evidence mapping and source dossiers.add /revisionHistory — Established a permanent, hash-addressed baseline revision.The text below is copied verbatim from the published record. Each claim names the source dossiers that carry it; caveats stay attached to the claim they qualify.
clm-d9ff281a01c63b35
descriptive
Göteborg Energi, owned by the City of Gothenburg
clm-4ece933c33913549
descriptive
heats most of the city's apartment buildings
clm-1706de0e0c64be57
descriptive
three quarters of its district heat is energy recovered from industrial processes, waste incineration and sewage water
clm-9cdd99423be853d7
quantitative
Preem's refinery began delivering heat to the company in 1997
clm-e9a6e9eec4346e0f
descriptive
short-term heat-load forecasts combine the system's heat signature with weather forecasts
clm-b25a13543eeb1eb1
quantitative
since November 2020 the Rya accumulator tank has cut peak demand by up to 100 MW
clm-3abb87bab6585dc8
descriptive
The Flexus project is fitting a control unit to every district heating and cooling substation
clm-de9535d30ed322de
quantitative
with the aim of steering down up to 100 MW of customer demand in a shortage
clm-403f4bc189c439e2
quantitative
In a pilot run by Göteborg Energi in 2010 and 2011, five Gothenburg apartment buildings had their heating signal shifted in cycles for a year
clm-8fe1f6ab3b8e5624
quantitative
storing 0.1 kWh of heat per square metre of floor area very rarely moved indoor temperatures by more than ±0.5°C
clm-77e10efb5eab5678
quantitative
A simulation built on the pilot estimated that using 20% of the heated floor area this way would halve the daily variation in heat load
clm-3af419a017f24a0f
quantitative
Gothenburg has tested buildings as heat stores since 2010
clm-544e43da82937c7b
quantitative
then in 900 newly built apartments under the EU-funded CELSIUS project, with a demo in the Kvillebäcken district
clm-8758225fa673e1a9
quantitative
the company still described the demand-side project as a potential of 30 to 60 MW for a few hours
clm-ed75cac51c4a1c2c
descriptive
how much of it can be realised is hard to predict because it depends on customers' economic decisions and their sense of comfort
clm-9429cb1d5638da00
quantitative
The tank at Rya, which the company controls itself, already shifts up to 100 MW
clm-af4fdbe03c8eb9e6
descriptive
Flexus, by the company's own account, has no direct effect on peaks in normal conditions
clm-683c2fced71ca1b5
descriptive
measures on the customer or production side can replace installed production capacity only marginally
This layer records what is known about each source, what is still missing, and the exact snapshot this page is rendering. A missing date, archive or hash stays visible as missing.
Awaiting operator and domain-expert review; publication of this revision implies neither.
sha256:c3ad7502e44ceb7bc332bcf47b740cf540da77f86d195ef8d26a16384a98d2ea
src-bb04a44d79fc6dacThe company's English about page: Göteborg Energi describes itself as Gothenburg's own energy company, owned by the City of Gothenburg.
src-86496738321188c8Annual and sustainability report for 2025. It states that the company is wholly owned by Göteborgs Stadshus AB, which the City of Gothenburg owns outright, that its district heating supplies most of the city's apartment buildings, and that three quarters of its district heat comes from energy recovered from industrial processes, waste incineration and sewage water.
src-71ed90dd1e82354fJoint slides by a Göteborg Energi and a Preem employee for an industry seminar on surplus heat. They state that Preem began delivering heat to Göteborg Energi in 1997 and give the refinery's 2016 and 2017 heat deliveries; the slides carry no date of their own.
src-d79382b61c47c7baPapers sent to the city council with Göteborg Energi's own report on cutting district heating peaks. It describes weather-forecast load prediction, the Rya accumulator tank in operation since November 2020 and its peak reduction of up to 100 MW, the Flexus project fitting a control unit to every district heating and cooling substation, and the Demand Side Management project, whose potential the company estimates at 30–60 MW for a few hours. It records the company's conclusion that customer-side and production-side measures can replace installed capacity only marginally.
src-fe03c1be74567faaPeer-reviewed article (Applied Energy, vol. 137) on a pilot test in five multifamily residential buildings in Gothenburg, in which the outdoor-temperature signal was adjusted in cycles over 52 weeks while heat delivery and indoor temperature were measured. Heavy concrete buildings tolerated relatively large variations in heat delivery; storing 0.1 kWh per square metre of floor area very rarely moved indoor temperature by more than ±0.5°C.
src-2515313e8ae925a8Licentiate thesis funded by Göteborg Energi. It dates the pilot to 2010 and 2011, says the measurements were carried out by Göteborg Energi, and reports a simulation of Gothenburg's network in which short-term storage in 20% of the heated floor area would halve the daily variation in heat load.
src-4313ce5c8f68475dThe European Commission's page on the Gothenburg site of the CELSIUS project: 900 newly built apartments, about 75,000 square metres of living area, connected to district heating and used as short-term thermal storage. It says information on technical and financial performance will be available at a later stage.
src-4a58fac3c44715eaProject page for CELSIUS: an EU FP7 project running from April 2013 to December 2017, with Gothenburg among five participating cities.
src-f77643589018e4b1Webinar listing in the CELSIUS toolkit presenting Göteborg Energi's work on residential buildings as thermal storage, with a focus on early results from a demo implementation in Kvillebäcken.