 "schemaVersion": "1.0.0",
 "constitutionVersion": "1.0.0",
 "createdAt": "2026-08-12T00:00:00Z",
 "description": "Append-only Evidence Passport records. Old revisions are immutable; corrections create a new revision and preserve the previous permalink.",
 "entity": {
  "type": "project",
  "id": "gothenburg-district-heating-waste-heat",
  "title": "Göteborg Energi's District Heating: Recovered Heat, Forecast Control and Buildings as Heat Stores",
  "canonicalUrl": "https://1001smartcities.org/projects/gothenburg-district-heating-waste-heat/"
 },
 "currentRevisionId": "2026-11-11-baseline",
 "revisions": [
  {
   "id": "2026-11-11-baseline",
   "createdAt": "2026-11-11T17:02:45Z",
   "effectiveAt": "2026-11-11",
   "changeType": "baseline",
   "summary": "Created the first structured Evidence Passport with 18 claims and 9 source dossiers.",
   "preparedBy": {
    "type": "automation",
    "label": "AI-assisted evidence preparation",
    "humanApproved": false
   },
   "review": {
    "status": "unreviewed",
    "by": null,
    "date": null,
    "note": "Awaiting operator and domain-expert review; publication of this revision implies neither."
   },
   "changes": [
    {
     "operation": "add",
     "path": "/evidencePassport",
     "summary": "Added claim-level evidence mapping and source dossiers."
    },
    {
     "operation": "add",
     "path": "/revisionHistory",
     "summary": "Established a permanent, hash-addressed baseline revision."
    }
   ],
   "snapshotHash": "sha256:c3ad7502e44ceb7bc332bcf47b740cf540da77f86d195ef8d26a16384a98d2ea",
   "snapshot": {
    "asOf": "2026-11-11",
    "projectFingerprint": "sha256:31032b0116f323d00bfa12e179cff02f262fea62bd59fc5d3d1505ed158cdc46",
    "assurance": {
     "status": "unreviewed",
     "scope": "evidence-passport-revision",
     "statement": "AI-assisted structural preparation. This revision has not been reviewed by a human or subject-matter expert.",
     "machineChecks": [
      "schema",
      "publication-diff-contract",
      "material-project-fingerprint",
      "claim-text-drift",
      "source-reference-resolution",
      "complete-source-dossier",
      "snapshot-hash"
     ]
    },
    "projectState": {
     "status": "live",
     "outcome": "ongoing",
     "evidenceGrade": "peer-reviewed",
     "timeline": {
      "started": 2010,
      "ended": null
     }
    },
    "governance": {
     "operator": "Göteborg Energi AB, wholly owned by the City of Gothenburg through Göteborgs Stadshus AB",
     "actorTypes": [
      "utility",
      "research"
     ],
     "fundingModel": "utility",
     "fundingDescription": "Göteborg Energi's own investment; the building-storage research was funded by the company, and the 900-apartment demonstrator was part of the EU FP7 project CELSIUS.",
     "cost": null,
     "ownership": null,
     "decisionRights": null,
     "exitConditions": null
    },
    "claims": [
     {
      "id": "clm-d9ff281a01c63b35",
      "field": "snippet",
      "text": "Göteborg Energi, owned by the City of Gothenburg",
      "statementKind": "descriptive",
      "textMode": "verbatim-from-project-record",
      "mappingStatus": "mapped",
      "sourceRefs": [
       "src-bb04a44d79fc6dac",
       "src-86496738321188c8"
      ],
      "supportNote": "The company's own about page says it is owned by the City of Gothenburg; the annual report specifies wholly owned by Göteborgs Stadshus AB, which the city owns outright.",
      "caveat": null,
      "interpretation": {
       "added": false,
       "interpolation": false,
       "note": "The passport copies the published claim and its recorded source mapping without adding a conclusion."
      }
     },
     {
      "id": "clm-4ece933c33913549",
      "field": "snippet",
      "text": "heats most of the city's apartment buildings",
      "statementKind": "descriptive",
      "textMode": "verbatim-from-project-record",
      "mappingStatus": "mapped",
      "sourceRefs": [
       "src-86496738321188c8"
      ],
      "supportNote": "The 2025 report says the district heating system supplies most apartment buildings in Gothenburg with heat.",
      "caveat": null,
      "interpretation": {
       "added": false,
       "interpolation": false,
       "note": "The passport copies the published claim and its recorded source mapping without adding a conclusion."
      }
     },
     {
      "id": "clm-1706de0e0c64be57",
      "field": "snippet",
      "text": "three quarters of its district heat is energy recovered from industrial processes, waste incineration and sewage water",
      "statementKind": "descriptive",
      "textMode": "verbatim-from-project-record",
      "mappingStatus": "mapped",
      "sourceRefs": [
       "src-86496738321188c8"
      ],
      "supportNote": "The report states that three quarters of the company's district heat comes from energy recovered from industrial processes, waste incineration and sewage water.",
      "caveat": "The share is the company's own figure; heat from sewage water reaches the network through electrically driven heat pumps.",
      "interpretation": {
       "added": false,
       "interpolation": false,
       "note": "The passport copies the published claim and its recorded source mapping without adding a conclusion."
      }
     },
     {
      "id": "clm-9cdd99423be853d7",
      "field": "snippet",
      "text": "Preem's refinery began delivering heat to the company in 1997",
      "statementKind": "quantitative",
      "textMode": "verbatim-from-project-record",
      "mappingStatus": "mapped",
      "sourceRefs": [
       "src-71ed90dd1e82354f"
      ],
      "supportNote": "Slides presented jointly by Göteborg Energi and Preem state that Preem began delivering heat to Göteborg Energi in 1997.",
      "caveat": null,
      "interpretation": {
       "added": false,
       "interpolation": false,
       "note": "The passport copies the published claim and its recorded source mapping without adding a conclusion."
      }
     },
     {
      "id": "clm-e9a6e9eec4346e0f",
      "field": "snippet",
      "text": "short-term heat-load forecasts combine the system's heat signature with weather forecasts",
      "statementKind": "descriptive",
      "textMode": "verbatim-from-project-record",
      "mappingStatus": "mapped",
      "sourceRefs": [
       "src-d79382b61c47c7ba"
      ],
      "supportNote": "The company's report says mathematical models combining the system's heat-load signature with weather forecasts underlie its short-term heat-load forecasts, run in the optimisation software Energy Optima 3.",
      "caveat": null,
      "interpretation": {
       "added": false,
       "interpolation": false,
       "note": "The passport copies the published claim and its recorded source mapping without adding a conclusion."
      }
     },
     {
      "id": "clm-b25a13543eeb1eb1",
      "field": "snippet",
      "text": "since November 2020 the Rya accumulator tank has cut peak demand by up to 100 MW",
      "statementKind": "quantitative",
      "textMode": "verbatim-from-project-record",
      "mappingStatus": "mapped",
      "sourceRefs": [
       "src-d79382b61c47c7ba"
      ],
      "supportNote": "The report says the Rya accumulator tank went into operation in November 2020 and has since reduced peak-load demand by up to 100 MW.",
      "caveat": "The 100 MW is the company's own figure for the largest shift, not a measured annual saving.",
      "interpretation": {
       "added": false,
       "interpolation": false,
       "note": "The passport copies the published claim and its recorded source mapping without adding a conclusion."
      }
     },
     {
      "id": "clm-3abb87bab6585dc8",
      "field": "snippet",
      "text": "The Flexus project is fitting a control unit to every district heating and cooling substation",
      "statementKind": "descriptive",
      "textMode": "verbatim-from-project-record",
      "mappingStatus": "mapped",
      "sourceRefs": [
       "src-d79382b61c47c7ba"
      ],
      "supportNote": "The report says all district heating and district cooling substations will get a control unit installed within the next three years under the Flexus project.",
      "caveat": null,
      "interpretation": {
       "added": false,
       "interpolation": false,
       "note": "The passport copies the published claim and its recorded source mapping without adding a conclusion."
      }
     },
     {
      "id": "clm-de9535d30ed322de",
      "field": "snippet",
      "text": "with the aim of steering down up to 100 MW of customer demand in a shortage",
      "statementKind": "quantitative",
      "textMode": "verbatim-from-project-record",
      "mappingStatus": "mapped",
      "sourceRefs": [
       "src-d79382b61c47c7ba"
      ],
      "supportNote": "The report gives Flexus the goal of regulating down and redirecting customers' heat demand by up to 100 MW in a shortage situation.",
      "caveat": null,
      "interpretation": {
       "added": false,
       "interpolation": false,
       "note": "The passport copies the published claim and its recorded source mapping without adding a conclusion."
      }
     },
     {
      "id": "clm-403f4bc189c439e2",
      "field": "impact",
      "text": "In a pilot run by Göteborg Energi in 2010 and 2011, five Gothenburg apartment buildings had their heating signal shifted in cycles for a year",
      "statementKind": "quantitative",
      "textMode": "verbatim-from-project-record",
      "mappingStatus": "mapped",
      "sourceRefs": [
       "src-2515313e8ae925a8",
       "src-fe03c1be74567faa"
      ],
      "supportNote": "The thesis dates the test to 2010 and 2011 and says the measurements were carried out by Göteborg Energi; the peer-reviewed article describes five multifamily residential buildings in Gothenburg whose outdoor-temperature signal was adjusted in cycles over 52 weeks.",
      "caveat": "The research was funded by Göteborg Energi.",
      "interpretation": {
       "added": false,
       "interpolation": false,
       "note": "The passport copies the published claim and its recorded source mapping without adding a conclusion."
      }
     },
     {
      "id": "clm-8fe1f6ab3b8e5624",
      "field": "impact",
      "text": "storing 0.1 kWh of heat per square metre of floor area very rarely moved indoor temperatures by more than ±0.5°C",
      "statementKind": "quantitative",
      "textMode": "verbatim-from-project-record",
      "mappingStatus": "mapped",
      "sourceRefs": [
       "src-fe03c1be74567faa"
      ],
      "supportNote": "The article concludes that storing 0.1 kWh per square metre of floor area will very rarely cause indoor temperature variations larger than ±0.5°C in a heavy building.",
      "caveat": null,
      "interpretation": {
       "added": false,
       "interpolation": false,
       "note": "The passport copies the published claim and its recorded source mapping without adding a conclusion."
      }
     },
     {
      "id": "clm-77e10efb5eab5678",
      "field": "impact",
      "text": "A simulation built on the pilot estimated that using 20% of the heated floor area this way would halve the daily variation in heat load",
      "statementKind": "quantitative",
      "textMode": "verbatim-from-project-record",
      "mappingStatus": "mapped",
      "sourceRefs": [
       "src-2515313e8ae925a8"
      ],
      "supportNote": "The thesis simulates Gothenburg's network on the basis of the pilot and finds that short-term storage in 20% of the heated floor area would decrease the daily heat-load variation by 50%.",
      "caveat": "This is a model result, not a measured outcome.",
      "interpretation": {
       "added": false,
       "interpolation": false,
       "note": "The passport copies the published claim and its recorded source mapping without adding a conclusion."
      }
     },
     {
      "id": "clm-3af419a017f24a0f",
      "field": "lesson",
      "text": "Gothenburg has tested buildings as heat stores since 2010",
      "statementKind": "quantitative",
      "textMode": "verbatim-from-project-record",
      "mappingStatus": "mapped",
      "sourceRefs": [
       "src-2515313e8ae925a8",
       "src-d79382b61c47c7ba"
      ],
      "supportNote": "The thesis dates the first pilot to 2010–2011; the 2026 report describes the Demand Side Management project as still ongoing.",
      "caveat": null,
      "interpretation": {
       "added": false,
       "interpolation": false,
       "note": "The passport copies the published claim and its recorded source mapping without adding a conclusion."
      }
     },
     {
      "id": "clm-544e43da82937c7b",
      "field": "lesson",
      "text": "then in 900 newly built apartments under the EU-funded CELSIUS project, with a demo in the Kvillebäcken district",
      "statementKind": "quantitative",
      "textMode": "verbatim-from-project-record",
      "mappingStatus": "mapped",
      "sourceRefs": [
       "src-4313ce5c8f68475d",
       "src-f77643589018e4b1",
       "src-4a58fac3c44715ea"
      ],
      "supportNote": "The Commission's site page says 900 newly built apartments in Gothenburg are used as short-term thermal storage within CELSIUS; the webinar listing names the demo Kvillebäcken; the project page identifies CELSIUS as an FP7 project running 2013–2017.",
      "caveat": "The Commission's page says performance information would follow later; no measured results from the apartment demonstrator were found.",
      "interpretation": {
       "added": false,
       "interpolation": false,
       "note": "The passport copies the published claim and its recorded source mapping without adding a conclusion."
      }
     },
     {
      "id": "clm-8758225fa673e1a9",
      "field": "lesson",
      "text": "the company still described the demand-side project as a potential of 30 to 60 MW for a few hours",
      "statementKind": "quantitative",
      "textMode": "verbatim-from-project-record",
      "mappingStatus": "mapped",
      "sourceRefs": [
       "src-d79382b61c47c7ba"
      ],
      "supportNote": "The report puts the potential of the Demand Side Management project at between 30 and 60 MW for a few hours.",
      "caveat": null,
      "interpretation": {
       "added": false,
       "interpolation": false,
       "note": "The passport copies the published claim and its recorded source mapping without adding a conclusion."
      }
     },
     {
      "id": "clm-ed75cac51c4a1c2c",
      "field": "lesson",
      "text": "how much of it can be realised is hard to predict because it depends on customers' economic decisions and their sense of comfort",
      "statementKind": "descriptive",
      "textMode": "verbatim-from-project-record",
      "mappingStatus": "mapped",
      "sourceRefs": [
       "src-d79382b61c47c7ba"
      ],
      "supportNote": "The report says how much of the potential can be realised is hard to foresee because it depends on factors customers control, such as economic decisions and their experience of comfort.",
      "caveat": null,
      "interpretation": {
       "added": false,
       "interpolation": false,
       "note": "The passport copies the published claim and its recorded source mapping without adding a conclusion."
      }
     },
     {
      "id": "clm-9429cb1d5638da00",
      "field": "lesson",
      "text": "The tank at Rya, which the company controls itself, already shifts up to 100 MW",
      "statementKind": "quantitative",
      "textMode": "verbatim-from-project-record",
      "mappingStatus": "mapped",
      "sourceRefs": [
       "src-d79382b61c47c7ba"
      ],
      "supportNote": "The report says the Rya accumulator can shift peak-load production by up to about 90–100 MW for a few hours.",
      "caveat": null,
      "interpretation": {
       "added": false,
       "interpolation": false,
       "note": "The passport copies the published claim and its recorded source mapping without adding a conclusion."
      }
     },
     {
      "id": "clm-af4fdbe03c8eb9e6",
      "field": "lesson",
      "text": "Flexus, by the company's own account, has no direct effect on peaks in normal conditions",
      "statementKind": "descriptive",
      "textMode": "verbatim-from-project-record",
      "mappingStatus": "mapped",
      "sourceRefs": [
       "src-d79382b61c47c7ba"
      ],
      "supportNote": "The report says Flexus has no direct effect on reducing peaks under normal conditions, though it may be developed further.",
      "caveat": null,
      "interpretation": {
       "added": false,
       "interpolation": false,
       "note": "The passport copies the published claim and its recorded source mapping without adding a conclusion."
      }
     },
     {
      "id": "clm-683c2fced71ca1b5",
      "field": "lesson",
      "text": "measures on the customer or production side can replace installed production capacity only marginally",
      "statementKind": "descriptive",
      "textMode": "verbatim-from-project-record",
      "mappingStatus": "mapped",
      "sourceRefs": [
       "src-d79382b61c47c7ba"
      ],
      "supportNote": "The city's cover memo records Göteborg Energi's conclusion that it sees no more than marginal measures on the customer or production side that could replace the need for installed production capacity.",
      "caveat": null,
      "interpretation": {
       "added": false,
       "interpolation": false,
       "note": "The passport copies the published claim and its recorded source mapping without adding a conclusion."
      }
     }
    ],
    "sources": [
     {
      "id": "src-bb04a44d79fc6dac",
      "title": "Göteborg Energi — About us",
      "url": "https://www.goteborgenergi.se/english/about-us",
      "publisher": {
       "name": null,
       "domain": "goteborgenergi.se",
       "classification": "not-classified"
      },
      "sourceType": "web-page",
      "language": "und",
      "role": "claim-evidence",
      "claimRefs": [
       "clm-d9ff281a01c63b35"
      ],
      "temporal": {
       "publishedAt": null,
       "updatedAt": null,
       "sourceCheckedAt": null,
       "recordLastVerifiedAt": "2026-11-11",
       "dossierCreatedAt": "2026-11-11",
       "retrievedAt": null,
       "status": "record-date-only"
      },
      "locator": {
       "type": "descriptive-source-note",
       "value": "The company's English about page: Göteborg Energi describes itself as Gothenburg's own energy company, owned by the City of Gothenburg.",
       "exact": false
      },
      "preservation": {
       "archiveUrl": null,
       "archivedAt": null,
       "contentHash": null,
       "status": "not-captured"
      }
     },
     {
      "id": "src-86496738321188c8",
      "title": "Göteborg Energi — Års- och hållbarhetsredovisning 2025 (2026)",
      "url": "https://goteborg.se/wps/PA_Pabolagshandlingar/file?id=60998",
      "publisher": {
       "name": null,
       "domain": "goteborg.se",
       "classification": "not-classified"
      },
      "sourceType": "web-page",
      "language": "und",
      "role": "claim-evidence",
      "claimRefs": [
       "clm-d9ff281a01c63b35",
       "clm-4ece933c33913549",
       "clm-1706de0e0c64be57"
      ],
      "temporal": {
       "publishedAt": null,
       "updatedAt": null,
       "sourceCheckedAt": null,
       "recordLastVerifiedAt": "2026-11-11",
       "dossierCreatedAt": "2026-11-11",
       "retrievedAt": null,
       "status": "record-date-only"
      },
      "locator": {
       "type": "descriptive-source-note",
       "value": "Annual and sustainability report for 2025. It states that the company is wholly owned by Göteborgs Stadshus AB, which the City of Gothenburg owns outright, that its district heating supplies most of the city's apartment buildings, and that three quarters of its district heat comes from energy recovered from industrial processes, waste incineration and sewage water.",
       "exact": false
      },
      "preservation": {
       "archiveUrl": null,
       "archivedAt": null,
       "contentHash": null,
       "status": "not-captured"
      }
     },
     {
      "id": "src-71ed90dd1e82354f",
      "title": "Göteborg Energi and Preem — Samarbetet mellan Preem och Göteborg Energi (seminar slides)",
      "url": "https://www.energiforetagen.se/globalassets/energiforetagen/det-erbjuder-vi/sakomraden/restvarmeseminarium/par-mann.pdf",
      "publisher": {
       "name": null,
       "domain": "energiforetagen.se",
       "classification": "not-classified"
      },
      "sourceType": "pdf",
      "language": "und",
      "role": "claim-evidence",
      "claimRefs": [
       "clm-9cdd99423be853d7"
      ],
      "temporal": {
       "publishedAt": null,
       "updatedAt": null,
       "sourceCheckedAt": null,
       "recordLastVerifiedAt": "2026-11-11",
       "dossierCreatedAt": "2026-11-11",
       "retrievedAt": null,
       "status": "record-date-only"
      },
      "locator": {
       "type": "descriptive-source-note",
       "value": "Joint slides by a Göteborg Energi and a Preem employee for an industry seminar on surplus heat. They state that Preem began delivering heat to Göteborg Energi in 1997 and give the refinery's 2016 and 2017 heat deliveries; the slides carry no date of their own.",
       "exact": false
      },
      "preservation": {
       "archiveUrl": null,
       "archivedAt": null,
       "contentHash": null,
       "status": "not-captured"
      }
     },
     {
      "id": "src-d79382b61c47c7ba",
      "title": "Göteborgs Stad — Redovisning av uppdrag rörande minskning av koldioxidutsläpp och minskat effektuttag av fjärrvärme, Handling 2026 nr 141 (3 Jun 2026)",
      "url": "https://www4.goteborg.se/prod/Intraservice/Namndhandlingar/SamrumPortal.nsf/318349D69A2EF6CFC1258E5A00406820/$File/Handling_2026_nr_141.pdf",
      "publisher": {
       "name": null,
       "domain": "www4.goteborg.se",
       "classification": "not-classified"
      },
      "sourceType": "pdf",
      "language": "und",
      "role": "claim-evidence",
      "claimRefs": [
       "clm-e9a6e9eec4346e0f",
       "clm-b25a13543eeb1eb1",
       "clm-3abb87bab6585dc8",
       "clm-de9535d30ed322de",
       "clm-3af419a017f24a0f",
       "clm-8758225fa673e1a9",
       "clm-ed75cac51c4a1c2c",
       "clm-9429cb1d5638da00",
       "clm-af4fdbe03c8eb9e6",
       "clm-683c2fced71ca1b5"
      ],
      "temporal": {
       "publishedAt": "2026-06-03",
       "updatedAt": null,
       "sourceCheckedAt": null,
       "recordLastVerifiedAt": "2026-11-11",
       "dossierCreatedAt": "2026-11-11",
       "retrievedAt": null,
       "status": "publication-and-record-dates-recorded"
      },
      "locator": {
       "type": "descriptive-source-note",
       "value": "Papers sent to the city council with Göteborg Energi's own report on cutting district heating peaks. It describes weather-forecast load prediction, the Rya accumulator tank in operation since November 2020 and its peak reduction of up to 100 MW, the Flexus project fitting a control unit to every district heating and cooling substation, and the Demand Side Management project, whose potential the company estimates at 30–60 MW for a few hours. It records the company's conclusion that customer-side and production-side measures can replace installed capacity only marginally.",
       "exact": false
      },
      "preservation": {
       "archiveUrl": null,
       "archivedAt": null,
       "contentHash": null,
       "status": "not-captured"
      }
     },
     {
      "id": "src-fe03c1be74567faa",
      "title": "Kensby, Trüschel & Dalenbäck — Potential of residential buildings as thermal energy storage in district heating systems, Applied Energy (Jan 2015)",
      "url": "https://research.chalmers.se/en/publication/209419",
      "publisher": {
       "name": null,
       "domain": "research.chalmers.se",
       "classification": "not-classified"
      },
      "sourceType": "web-page",
      "language": "und",
      "role": "claim-evidence",
      "claimRefs": [
       "clm-403f4bc189c439e2",
       "clm-8fe1f6ab3b8e5624"
      ],
      "temporal": {
       "publishedAt": null,
       "updatedAt": null,
       "sourceCheckedAt": null,
       "recordLastVerifiedAt": "2026-11-11",
       "dossierCreatedAt": "2026-11-11",
       "retrievedAt": null,
       "status": "record-date-only"
      },
      "locator": {
       "type": "descriptive-source-note",
       "value": "Peer-reviewed article (Applied Energy, vol. 137) on a pilot test in five multifamily residential buildings in Gothenburg, in which the outdoor-temperature signal was adjusted in cycles over 52 weeks while heat delivery and indoor temperature were measured. Heavy concrete buildings tolerated relatively large variations in heat delivery; storing 0.1 kWh per square metre of floor area very rarely moved indoor temperature by more than ±0.5°C.",
       "exact": false
      },
      "preservation": {
       "archiveUrl": null,
       "archivedAt": null,
       "contentHash": null,
       "status": "not-captured"
      }
     },
     {
      "id": "src-2515313e8ae925a8",
      "title": "Johan Kensby, Chalmers — Buildings as thermal energy storage: pilot test and large-scale implementation for district heating systems (licentiate thesis, 2015)",
      "url": "https://publications.lib.chalmers.se/records/fulltext/216470/216470.pdf",
      "publisher": {
       "name": null,
       "domain": "publications.lib.chalmers.se",
       "classification": "not-classified"
      },
      "sourceType": "pdf",
      "language": "und",
      "role": "claim-evidence",
      "claimRefs": [
       "clm-403f4bc189c439e2",
       "clm-77e10efb5eab5678",
       "clm-3af419a017f24a0f"
      ],
      "temporal": {
       "publishedAt": null,
       "updatedAt": null,
       "sourceCheckedAt": null,
       "recordLastVerifiedAt": "2026-11-11",
       "dossierCreatedAt": "2026-11-11",
       "retrievedAt": null,
       "status": "record-date-only"
      },
      "locator": {
       "type": "descriptive-source-note",
       "value": "Licentiate thesis funded by Göteborg Energi. It dates the pilot to 2010 and 2011, says the measurements were carried out by Göteborg Energi, and reports a simulation of Gothenburg's network in which short-term storage in 20% of the heated floor area would halve the daily variation in heat load.",
       "exact": false
      },
      "preservation": {
       "archiveUrl": null,
       "archivedAt": null,
       "contentHash": null,
       "status": "not-captured"
      }
     },
     {
      "id": "src-4313ce5c8f68475d",
      "title": "European Commission, Smart Cities Marketplace — CELSIUS Site Gothenburg",
      "url": "https://smart-cities-marketplace.ec.europa.eu/projects-and-sites/projects/celsius/celsius-site-gothenburg",
      "publisher": {
       "name": null,
       "domain": "smart-cities-marketplace.ec.europa.eu",
       "classification": "not-classified"
      },
      "sourceType": "web-page",
      "language": "und",
      "role": "claim-evidence",
      "claimRefs": [
       "clm-544e43da82937c7b"
      ],
      "temporal": {
       "publishedAt": null,
       "updatedAt": null,
       "sourceCheckedAt": null,
       "recordLastVerifiedAt": "2026-11-11",
       "dossierCreatedAt": "2026-11-11",
       "retrievedAt": null,
       "status": "record-date-only"
      },
      "locator": {
       "type": "descriptive-source-note",
       "value": "The European Commission's page on the Gothenburg site of the CELSIUS project: 900 newly built apartments, about 75,000 square metres of living area, connected to district heating and used as short-term thermal storage. It says information on technical and financial performance will be available at a later stage.",
       "exact": false
      },
      "preservation": {
       "archiveUrl": null,
       "archivedAt": null,
       "contentHash": null,
       "status": "not-captured"
      }
     },
     {
      "id": "src-4a58fac3c44715ea",
      "title": "European Commission, Smart Cities Marketplace — CELSIUS project",
      "url": "https://smart-cities-marketplace.ec.europa.eu/projects-and-sites/projects/celsius",
      "publisher": {
       "name": null,
       "domain": "smart-cities-marketplace.ec.europa.eu",
       "classification": "not-classified"
      },
      "sourceType": "web-page",
      "language": "und",
      "role": "claim-evidence",
      "claimRefs": [
       "clm-544e43da82937c7b"
      ],
      "temporal": {
       "publishedAt": null,
       "updatedAt": null,
       "sourceCheckedAt": null,
       "recordLastVerifiedAt": "2026-11-11",
       "dossierCreatedAt": "2026-11-11",
       "retrievedAt": null,
       "status": "record-date-only"
      },
      "locator": {
       "type": "descriptive-source-note",
       "value": "Project page for CELSIUS: an EU FP7 project running from April 2013 to December 2017, with Gothenburg among five participating cities.",
       "exact": false
      },
      "preservation": {
       "archiveUrl": null,
       "archivedAt": null,
       "contentHash": null,
       "status": "not-captured"
      }
     },
     {
      "id": "src-f77643589018e4b1",
      "title": "European Commission, Smart Cities Marketplace — Webinar: Using buildings as thermal energy storages – Kvillebäcken demo (31 Jan 2020)",
      "url": "https://smart-cities-marketplace.ec.europa.eu/insights/solutions/webinar-using-buildings-thermal-energy-storages-kvillebacken-demo",
      "publisher": {
       "name": null,
       "domain": "smart-cities-marketplace.ec.europa.eu",
       "classification": "not-classified"
      },
      "sourceType": "web-page",
      "language": "und",
      "role": "claim-evidence",
      "claimRefs": [
       "clm-544e43da82937c7b"
      ],
      "temporal": {
       "publishedAt": "2020-01-31",
       "updatedAt": null,
       "sourceCheckedAt": null,
       "recordLastVerifiedAt": "2026-11-11",
       "dossierCreatedAt": "2026-11-11",
       "retrievedAt": null,
       "status": "publication-and-record-dates-recorded"
      },
      "locator": {
       "type": "descriptive-source-note",
       "value": "Webinar listing in the CELSIUS toolkit presenting Göteborg Energi's work on residential buildings as thermal storage, with a focus on early results from a demo implementation in Kvillebäcken.",
       "exact": false
      },
      "preservation": {
       "archiveUrl": null,
       "archivedAt": null,
       "contentHash": null,
       "status": "not-captured"
      }
     }
    ],
    "coverage": {
     "claimsTotal": 18,
     "claimsMapped": 18,
     "sourcesTotal": 9,
     "sourcesUsedByClaims": 9,
     "sourcesWithPublicationDate": 2,
     "sourcesWithArchive": 0,
     "sourcesWithExactLocator": 0,
     "sourcesWithContentHash": 0
    },
    "limits": [
     "Publisher names and source languages have not yet been classified; domains are recorded without guessing.",
     "Existing source notes are descriptive locators, not page- or paragraph-exact citations.",
     "A missing archive, publication date or content hash is shown as null rather than inferred.",
     "The project-level evidence grade ranks the strongest source in the entry; it is not a truth score for every claim."
    ]
   }
  }
 ]
}